BGDXD - XUPER 680 CGS
- MSDS: BGDXD
- Manufacturer: EUTECTIC CORP
- Product Name: XUPER 680 CGS
- National Stock Number: 3439-01-019-0694
Product Identification
Product ID:XUPER 680 CGS
MSDS Date:03/20/1990
FSC:3439
NIIN:01-019-0694
MSDS Number: BGDXD
Responsible Party
FLUSHING, NY 11358-9981
US
Emergency Phone: 718-358-4000
Info Phone: 718-358-4000
Cage: 72271
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: 72271
Ingredients
IRON
CAS: 7439-89-6
RTECS: NO4565500
OSHA PEL 5 MG/M3 (MFR)
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
POTASSIUM ALUMINUM SILICATE (FELDSPAR)
CAS: 68476-25-5
SODIUM SILICATE
CAS: 1344-09-8
MANGANESE (SARA III)
CAS: 7439-96-5
RTECS: OO9275000
OSHA PEL (C) 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST 9293
BARIUM CARBONATE
CAS: 513-77-9
RTECS: CQ8600000
CALCIUM FLUORIDE
CAS: 7789-75-5
RTECS: EW1760000
OSHA PEL 2.5 MG/M3 (F)
ACGIH TLV: 2.5 MG/M3 (F); 8990
POTASSIUM SILICATE
CAS: 1312-76-1
FERROCHROME/FERROCHROMIUM
CAS: 11114-46-8
RTECS: LK0750000
COBALT ALUMINUM OXIDE
OSHA PEL 0.05 MG/M3 FUME(CO)
ACGIH TLV: 0.05 MG/M3 FUME(CO)
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE-EXPOSURE TO WELDING FUMES MAY
CAUSE DRYNESS & IRRITATION OF EYES,SKIN,NOSE &
THROAT.INHALATION:NAUSEA,DIZZINESS & LUNG DAMAGE.ARC RAYS CAN
INJURE EYES & BURN SKIN.
Explanation of Carcinogenicity:NICKEL AND CHROMIUM ARE CONSIDERED
CARCINOGENS BY NTP AND IARC.
Effects of Overexposure:EXPOSURE TO WELDING FUMES MAY RESULT IN
DISCOMFORT SUCH AS DIZZINESS, NAUSEA, FEVER, DRYNESS AND/OR
IRRITATION OF NOSE, THROAT AND EYES.
Medical Cond Aggravated by Exposure:SOME WORKERS MAY BE AFFECTED BY A
PRE-EXISTING CONDITION OR OTHER OCCUPATIONAL ILLNESS BECAUSE OF THE
WIDE VARIATION IN INDIVIDUAL SUSCEPTIBILITIES.
First Aid
First Aid:INHALATION:REMOVE TO FRESH AIR.CALL A PHYSICIAN.IF ELECTRICAL
SHOCK:TURN OFF POWER.ADMINISTER FIRST AID.REMOVE FROM EXPOSURE AREA
AND CALL FOR MEDICAL AID.GIVE OXYGEN/CPR IF NEEDED.IF NO DETECTABLE
PU LSE,BEGIN EXTERNAL HEART MASSAGE.EMPLOYFIRST AID TECHNIQUES
RECOMMENDED BY THE AMERICAN RED CROSS.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL TO PUT OFF THE SURROUNDING FIRE.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:WELDING ARC AND SPARKS CAN IGNITE
COMBUSTIBLES AND FLAMMABLES.
Accidental Release
Spill Release Procedures:NOT RELEVANT
Handling
Handling and Storage Precautions:WEAR GLOVES AND FLAME RETARDANT
CLOTHING WHEN CUTTING, GRINDING OR WELDING. DO NOT EXPOSE SKIN TO
RADIATION WHEN HOT CUTTING OR WELDING.
Other Precautions:PROVIDE PROTECTIVE SCREENS TO SHIELD OTHERS. WHEN
ELECTRODES AND FLUXES ARE CONSUMED, THE FUME AND GAS DECOMPOSITION
PRODUCTS GENERATED ARE DIFFERENT IN FORM FROM THE INGREDIENTS
LISTED. NEW COMPOUNDS NOT IN THE ELECTRODES MAY FORM.
Exposure Controls
Respiratory Protection:USE WELD FUME RESPIRATOR OR AIR SUPPLIED
RESPIRATOR WHEN CUTTING, GRINDING OR WELDING IN A CONFINED SPACE OR
WHERE LOCAL EXHAUST OR GENERAL VENTILATION DOES NOT KEEP EXPOSURE
BELOW RECOMMENDED LIMITS. USE ONLY NIOSH APPROVED RESPIRATORS.
Ventilation:USE ENOUGH VENTILATION WHEN CUTTING, GRINDING OR WELDING TO
KEEP THE DUST, FUMES & GASES FROM THE WORKERS BREATHING ZONE
Protective Gloves:WELDERS LEATHER GLOVES
Eye Protection:WEAR HELMET/FACE SHIELD WITH FILTER LENS
Other Protective Equipment:FLAME RETARDANT CLOTHING WHEN CUTTING,
GRINDING OR WELDING. DO NOT EXPOSE SKIN TO RADIATION.AVOID ELECTRIC
SHOCKS.
Work Hygienic Practices:WASH HANDS THOROUGHLY BEFORE EATING OR
DRINKING.
Supplemental Safety and Health
WELDING AND HOT CUTTING FUMES & GASES CANNOT BE CLASSIFIED SIMPLY.
THEIR COMPOSITION AND QUANTITY ARE DEPENDENT ON THE METAL BEING
WELDED, THE PROCEDURES, PROCESSES AND THE TYPE OF WIRE OR
ELECTRODES USED. OTHER INFLUENCING FACTORS ARE THEPRESENCE OF
CONTAMINANTS. CHLORINATED SOLVENTS MAY DECOMPOSE TO TOXIC GASES.
Chemical Properties
HCC:N1
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:SPARKS AND OPEN FLAMES
Hazardous Decomposition Products:FLUORIDES,COMPLEX OXIDES OF
IRON,MANGANESE,SILICON,CHROMIUM,NICKEL,MOLYBDENUM,COPPER,CO,CO2,OZO
NE AND NITROGEN OXIDE.
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL REGULATIONS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.